The FRI deposition profiles highlight that the MDI/ AeroChamber Plus* Flow Vu* VHC system delivered an appreciably greater percentage of drug to the lung region than either of the two DPIs.
The influence of inhalation flow profile was less with the MDI/VHC system and differed between the two DPIs.
The FRI deposition profiles highlight that the MDI/AeroChamber Plus* Flow-Vu* VHC delivered a significantly greater percentage of drug to the lung region than either of the two DPIs, irrespective of flow rate.
This was reflected in much higher modelled oropharyngeal deposition for the two DPIs.
The influence of inhalation flow profile was significant for one of the DPIs.
The FRI deposition profiles highlighted significant differences between the VHCs on test, with intrathoracic delivery for the AeroChamber Plus* Flow-Vu* VHC system being almost double that of the other two VHC systems and being similar to the MDI alone with perfect coordination
Accelerate and scale your digital Metered Dose Inhaler (MDI) portfolio programs with the trusted Top Mounted Actuation Indicator (TMAI) technology platform.
More consistent dose delivery was achieved with the breath actuated technology rather than breath enhanced. Delivering medication only when the patient inhales would result in more stable therapy if I:E ratio was to change with disease< progression or if the patient took breaks to talk during treatment.
More consistent dose delivery was achieved with the breath actuated technology rather than breath enhanced. Delivering medication only when the patient inhales would result in more stable therapy if I:E ratio was to change with disease< progression or if the patient took breaks to talk during treatment.
More consistent dose delivery was achieved with the breath actuated technology rather than breath enhanced. Delivering medication only when the patient inhales would result in more stable therapy if I:E ratio was to change with disease< progression or if the patient took breaks to talk during treatment.
The delivery of medication from the AEROECLIPSE* II BAN* to the lungs was not affected by the incorporation of the Aerobika* OPEP device. Aerosol deposition within the lung was unaltered by the addition of the OPEP device as evidenced by the near identical percentage of the dose being deposited in both the peripheral and central airways.
BAN+OPEP therapy could offer the clinician the opportunity for combined treatment thereby reducing the time needed for the patient to take both nebulizer and OPEP treatments separately.