Skip to main content

AEROCHAMBER* mini Anti-Static Holding Chamber

For use with an MDI for mechanically ventilated patients

The AEROCHAMBER* mini Anti-Static Holding Chamber can be used in a ventilator circuit or with a resuscitation bag. Compact, the chamber minimizes dead space. This chamber is removed from the circuit following treatment.

  • Small volume chamber suitable for application in neonates and other patients with lower tidal volumes
  • Anti-static improves the reliability of medication delivery1
  • Ready to use directly out of the package – time saving with no pretreatment needed


1. Jason Suggett, et al. Use Of Valved Holding Chambers Without Pre-conditioning And The Influence Of Anti-static Materials. Journal of Aerosol Medicine and Pulmonary Drug Delivery 2014;28.

  • Asthma Management
  • Bronchiectasis
  • COPD
  • Cystic Fibrosis
  • Inhaler

Product Overview

Why is an inhaler always together with an AEROCHAMBER* mini spacer?

Use of a spacer simplifies coordination of MDI actuation and inhalation, reducing aerosol losses with poor hand-breath coordination.2

2. Douglas S Gardenhire, et al. A Guide To Aerosol Delivery Devices for Respiratory Therapists, 5th Edition. American Association for Respiratory Care 2023. 

Features

  • AERODOCK* Canister Port and a removable canister adaptor allows for use with all types of metered dose inhalers, including those with integrated dose counters
  • 15mm connector fits standard endotracheal tubes
  • Separate exhalation channel minimizes dead space for low tidal volume patients
  • Single-patient use, multiple use (replace with the circuit)

How to Use

Ventilator Circuit

Image
labelled diagram of aerochamber mini

A 15 mm Endotracheal Tube Connector | B Wye Connector | C Canister Port | D Canister Adapter

  • diagram showing how to disconnect the wye from the endotracheal tube

    Step 1:

    Disconnect the wye from the endotracheal tube. Connect the 15 mm endotracheal tube connector (A) to the endotracheal tube. Connect the wye connector (B) to the wye. The arrow on the chamber must point towards the patient and the canister port (C) must be on top.

Resuscitation Bag

diagram depicting how to use aerochamber mini with resuscitation bag

A 15 mm Endotracheal Tube Connector | B Wye Connector | C Canister Port | D Canister Adapter

  • diagram depicting how to attach resuscitation bag to aerochamber mini

    Step 1:

    Attach the resuscitation bag to the wye connector (B).

Cleaning

The device should not be cleaned. It can be replaced with the ventilator circuit. Refer to the instructions for use for additional information.

Data and Efficacy

Scientific and Performance Evidence

Trudell Medical International has an enviable history of strong leadership in creating innovative medical devices that enhance the quality of life for people of all ages - all backed by science and clinical evidence.

  • In Vitro Evaluation Of A Novel Ventilation Chamber (VC) For Delivery Of Aerosolized Medication To The Mechanically Ventilated Premature Infant

    In vitro study reports delivery of albuterol with the AeroChamber* mini Anti-Static Holding Chamber.

    Download
  • Specialty Chambers Study Summary

    A study compilation covering the full range of specialty application chambers that have been designed to deliver metered dose inhaler (MDI) aerosol medication within the hospital environment.

    Download

Product Information

For more detailed instructions on how to care for your device, download our printables.

  • AEROCHAMBER* mini Anti-Static Holding Chamber Instructions for Use

    Download
  • AEROCHAMBER* VENT Holding Chamber Product Information Sheet

    Refer to the instructions for use for additional information.